Development and Validation of Stability Indicating RP-HPLC Method for the Simultaneous Estimation of Dapagliflozin Propanediol and Metformin Hydrochloride in Tablet Dosage Form

Authors

  • Nikita Shaileshbhai Patel K. B. Institute of Pharmaceutical Education and Research, Sector-23, Gandhinagar- 382023, Gujarat, India
  • Bhavesh Hirabhai Patel K. B. Institute of Pharmaceutical Education and Research, Sector-23, Gandhinagar- 382023, Gujarat, India

Abstract

A rapid, precise, accurate, specific and simple stability indicating RP-HPLC method was developed for simultaneous estimation of Dapagliflozin Propanediol (DAPA) and Metformin Hydrochloride (MET) in its tablet dosage form. Method was performed on a column C8 Thermoquest, hypersil division of dimension 250 mm × 4.60 mm having particle size 5 micron. The mobile phase used in the method was 10 mM Ammonium Acetate buffer (pH- 4), Methanol and Acetonitrile in proportion of 30:65:05 respectively. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, range, precision, accuracy, robustness, LOD, LOQ and system suitability. The flow rate was maintained at 0.8 ml/ min and effluent was monitored at 227 nm. The retention time were observed 5.988 min and 4.661 min for DAPA and MET respectively.  The standard curve was found linear over range of 60-140 μg/ml for DAPA and 300-700 μg/ml for MET with correlation coefficient of 0.9996 for DAPA and 0.9994 for MET. The limit of Detection (LOD) of this method was 1.121 μg/ml for DAPA and 6.162 μg/ml for MET. The limit of Quantitation (LOQ) of this method was 3.396 μg/ml for DAPA and 18.674 μg/ml for MET.  The percentage recovery was found to be in the range of 98-102% at three different levels of a standard addition. The precision (repeatability, intra-day and inter-day) of the method was within the limit (RSD<2%). Degradation products produced because of stress studies did not interfere with the detection of DAPA and MET and the assay can thus be considered stability-indicating. Combination tablet was successfully analysed using the developed method.

Keywords:

Dapagliflozin, Metformin, RP-HPLC, Force degradation, Stability, Validation

DOI

https://doi.org/10.25004/IJPSDR.2020.120609

References

Rang HP, Dale MM, R it ter JM, Flower RJ. Rang and Dale’s Pharmacology. Elsevier. 2007.

American Diabetes Association (ADA). Classification and Diagnosis of Diabetes: Standards of Medical Care in Diabetes-2018. Diabetes Care, 2018; 41(1): S13-S27.

https://www.diabetes.co.uk/diabetes-medication/antidiabetic-drugs.html [Last accessed on 17 Aug 2020].

Rosenstock J, Hansen L, Zee G, Li Y, Cook W, Hirshberg B and Iqbal N. Dual Add-on Therapy in Type 2 Diabetes Poorly Controlled With Metformin Monotherapy: A Randomized Double-Blind Trial of Saxagliptin Plus Dapagliflozin Addition Versus Single Addition of Saxagliptin or Dapagliflozin to Metformin. Diabetes Care. 2015 Mar; 38(3):376-383.

Quadri SS, Sonwane LV, Poul BN and Kamshette SN. Review on Stability Indicating Assay Methods (SIAMs). PharmaTutor. 2014; 2(8):16-31.

Eswarudu MM, Babu PS and Aswini R. A Novel RP-HPLC Method for Simultaneous Estimation of Dapagliflozin and Saxagliptin in Bulk and Pharmaceutical Dosage Form. Int J Pharm Sci Res. 2018; 9(12):5161–5167.

Nyola N and Jeyabalan GS. Development and validation of UV-Vis specctroscopy method for simultaneous estimation of Saxagliptin Hydrochloride and Metformin Hydrochloride in active pharmaceutical ingrident. J Pharm Educ Res. 2012; 3(2):19–23.

Jani BR, Shah KV and Kapupara PP. Development and Validation of UV Spectroscopic First Derivative Method for Simultaneous Estimation of Dapagliflozin and Metformin Hydrochloride in Synthetic Mixture. Journal of Bioequivalence Studies. 2015, 1(1):1-8.

Urooj A, Sundar PS, Vasanthi R, Raja MA, Dutt KR, Rao KNV and Ramana H. Development and Validation of RP-HPLC Method for Simultaneous Estimation of Dapagliflozin and Metformin in Bulk and in Synthetic Mixture. World J Pharm Pharm Sci. 2017, 6(7): 2139-2150.

Abdel-Gawad SA, Al-Tamimi AMS and Adam EH. Chromatographic Simultaneous Quantification of Dapagliflozin and Metformin Hydrochloride in Presence of their Degradation Products. Int J Biol Pharm Allied Sci. 2017 Oct, 6(10): 2007-2021.

Deepan T, Rao MB and Dhanaraju MD. Development of Validated Stability Indicating Assay Method for Simultaneous Estimation of Metformin and Dapagliflozin by RP- HPLC. Eur J Appl Sci. 2017; 9(4):189-199.

International Conference on Harmonization (1996) Technical Requirements for Registration of Pharmaceuticals for Human Use, Validation of Analytical Procedures: Validation of analytical procedures: Text and Methodology, ICH Q2 (R1); 2005.

Published

30-11-2020
Statistics
Abstract Display: 751
PDF Downloads: 980
Dimension Badge

How to Cite

“Development and Validation of Stability Indicating RP-HPLC Method for the Simultaneous Estimation of Dapagliflozin Propanediol and Metformin Hydrochloride in Tablet Dosage Form”. International Journal of Pharmaceutical Sciences and Drug Research, vol. 12, no. 6, Nov. 2020, pp. 660-7, https://doi.org/10.25004/IJPSDR.2020.120609.

Issue

Section

Research Article

How to Cite

“Development and Validation of Stability Indicating RP-HPLC Method for the Simultaneous Estimation of Dapagliflozin Propanediol and Metformin Hydrochloride in Tablet Dosage Form”. International Journal of Pharmaceutical Sciences and Drug Research, vol. 12, no. 6, Nov. 2020, pp. 660-7, https://doi.org/10.25004/IJPSDR.2020.120609.